d 7 7 keto cholesterol (Croda International Plc)
Structured Review
D 7 7 Keto Cholesterol, supplied by Croda International Plc, used in various techniques. Bioz Stars score: 95/100, based on 181 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/d+7+cholesterol/cholesterol-d7/pmc12955076-300-19-42
Average 95 stars, based on 181 article reviews
Images
Related Articles
other:Article Title: Specialization and adaptation in pollen sterol use by wild bees Article Snippet: Article Title: Cholesterol promotes both head group visibility and clustering of PI(4,5)P 2 driving unconventional secretion of Fibroblast Growth Factor 2 Article Snippet: Lipid standards were added prior to extractions, using a master mix containing 50 pmol Clinical Proteomics:Article Title: Obesity-Associated Hyperuricemia in Female Mice: A Reevaluation Article Snippet: .. To analyze cholesterol, cholesteryl esters, and triglycerides in plasma samples, 15 μL of each plasma sample was spiked with 5 pmol of Targeted Proteomics:Article Title: Stable reduction of STARD4 alters cholesterol regulation and lipid homeostasis Article Snippet: An Agilent Zorbax Rx-Sil column (inner diameter 2.1 x 100 mm) was used under the following conditions: mobile phase A (chloroform:methanol:1 M ammonium hydroxide, 89.9:10:0.1, v/v) and mobile phase B (chloroform:methanol:water:ammonium hydroxide, 55:39.9:5:0.1, v/v); 95% A for 2 min, linear gradient to 30% A over 18 min and held for 3 min, and linear gradient to 95% A over 2 min and held for 6 min. Sterols and glycerolipids were separated with reverse-phase HPLC using an isocratic mobile phase as before [ 34 ] except with an Agilent Zorbax Eclipse XDB-C18 column (4.6 x 100 mm). .. Quantification of lipid species was accomplished using multiple reaction monitoring (MRM) transitions that were developed in earlier studies [ 34 - 36 ] in conjunction with referencing of appropriate internal standards: PA 14:0/14:0, PC 14:0/14:0, PE 14:0/14:0, PG 15:0/15:0, PI 16:0/16:0, PS 14:0/14:0, BMP 14:0/14:0, APG 14:0/14:0, LPC 17:0, LPE 14:0, LPI 13:0, Cer d18:1/17:0, SM d18:1/12:0, dhSM d18:0/12:0, GalCer d18:1/12:0, GluCer d18:1/12:0, LacCer d18:1/12:0, D 7 -cholesterol, CE 17:0, MG 17:0, 4ME 16:0 diether DG, Article Title: Decreased surfactant lipids correlate with lung function in chronic obstructive pulmonary disease (COPD) Article Snippet: An Agilent Zorbax Rx-Sil column (inner diameter 2.1 x 100 mm) was used under the following conditions: mobile phase A (chloroform:methanol:1 M ammonium hydroxide, 89.9:10:0.1, v/v) and mobile phase B (chloroform:methanol:water:ammonium hydroxide, 55:39.9:5:0.1, v/v); 95% A for 2 min, linear gradient to 30% A over 18 min and held for 3 min, and linear gradient to 95% A over 2 min and held for 6 min. Sterols and glycerolipids were separated with reverse-phase HPLC using an isocratic mobile phase as before [ ] except with an Agilent Zorbax Eclipse XDB-C18 column (4.6 x 100 mm). .. Quantification of lipid species was accomplished using multiple reaction monitoring (MRM) transitions and instrument settings that were developed in earlier studies [ ] in conjunction with referencing of appropriate internal standards PA 14:0/14:0, PC 14:0/14:0, PE 14:0/14:0, PG 15:0/15:0, PI 17:0/20:4, PS 14:0/14:0, BMP 14:0/14:0, APG 14:0/14:0, LPC 17:0, LPE 14:0, LPI 13:0, Cer d18:1/17:0, SM d18:1/12:0, dhSM d18:0/12:0, GalCer d18:1/12:0, GluCer d18:1/12:0, LacCer d18:1/12:0, D 7 -cholesterol, CE 17:0, MG 17:0, 4ME 16:0 diether DG, Article Title: Mitofusins regulate lipid metabolism to mediate the development of lung fibrosis Article Snippet: An Agilent Zorbax Rx-Sil column (inner diameter 2.1 × 100 mm) was used under the following conditions: mobile phase A (chloroform:methanol:1 M ammonium hydroxide, 89.9:10:0.1, v/v) and mobile phase B (chloroform:methanol:water:ammonium hydroxide, 55:39.9:5:0.1, v/v); 95% A for 2 min, linear gradient to 30% A over 18 min and held for 3 min, and linear gradient to 95% A over 2 min and held for 6 min. Sterols and glycerolipids were separated with reverse-phase HPLC using an isocratic mobile phase as before except with an Agilent Zorbax Eclipse XDB-C18 column (4.6 × 100 mm). .. Quantification of lipid species was accomplished using multiple reaction monitoring (MRM) transitions that were developed in earlier studies in conjunction with referencing of appropriate internal standards: PA 14:0/14:0, PC 14:0/14:0, PE 14:0/14:0, PI 12:0/13:0, PS 14:0/14:0, SM d18:1/12:0, D 7 -cholesterol, CE 17:0, MG 17:0, 4ME 16:0 diether DG, Tissue:Article Title: Obese female mice do not exhibit overt hyperuricemia despite hepatic steatosis and impaired glucose tolerance Article Snippet: .. |
